Difference between Single Phase and Three Phase Transformer

What is the Difference Between 1-Phase Transformer & 3-Phase Transformer?

A transformer is an electrical machine used to increase (step-up) or decrease (step-down) the level of alternating voltage and current. It helps transfer electrical power efficiently from generating stations to different users, such as homes, offices, and industries. For example, power generated at a plant may be transmitted at a high voltage and then reduced to a safer, usable level before it reaches houses or factories. Although all transformers perform the same basic task, they are mainly divided into two types based on the supply system: the Single Phase and Three Phase Transformer. Each type serves a different purpose depending on the power demand and the application area.

Difference between Single Phase and Three Phase Transformer

The main difference between a single phase transformer and a three phase transformer lies in how they deliver electrical power. A single phase transformer provides a single-phase supply through two conductors—one is the Phase (Line) and the other is the Neutral (1P + 1N). This type is commonly used for smaller loads, such as household appliances or lighting circuits. In contrast, a three phase transformer delivers a three-phase supply through three Phase (Line) conductors and, if required, a Neutral conductor (3P + 1N). It is typically used in industrial or commercial systems where large amounts of power are needed, similar to how a three-lane highway allows more traffic to flow smoothly compared to a single-lane road.

Continue reading : Difference Between Contactor and Starter

Single Phase Transformer

A single phase transformer consists of a single pair of coils wound around a magnetic core. These coils act as the primary winding and the secondary winding, and they are electrically insulated from each other to prevent direct current flow between them. It has four terminals—two for the primary and two for the secondary side—representing the Phase and Neutral connections. Unlike more complex systems, it does not use winding configurations such as Star (Y) or Delta (Δ). To make the circuit work properly, both the Phase and Neutral wires must be connected, similar to how both rails are needed for a train to run smoothly.

In the United States, the primary winding of a single phase transformer is typically connected to 7200 volts, while the secondary winding delivers 120V and 240V for residential single phase power. In contrast, in the United Kingdom, European Union, and other IEC-standard countries, the primary operates at 11kV, and the secondary supplies 230V single phase power to households and small businesses.

Single Phase Transformer

Single phase transformers are often installed on utility poles near residential areas and are widely used across North America. Because they are less expensive and designed for lower power capacity, they are ideal for homes, small offices, and other light load applications, such as lighting or basic electrical appliances.

Detailed explanation on : Difference between Circuit Breaker and Fuse

Three Phase Transformer

A three phase transformer is essentially a combination of three single phase transformers connected together within one integrated unit. In another design, it can consist of three sets of high-inductance coils wound around a common magnetic core. These coils can be linked in several configurations, including Delta–Delta (Δ-Δ), Delta–Star (Δ-Y), Star–Star (Y-Y), or Star–Delta (Y-Δ), depending on the system requirements and how the load is distributed. These configurations determine how voltage and current flow between the primary and secondary windings—similar to how different road junctions guide traffic in various directions.

In the United States, the primary winding of a three phase transformer is commonly connected to 7200 volts, and the secondary winding delivers several voltage options such as 120V & 240V (single phase) and 208V, 277V, or 480V (three phase). Meanwhile, in the United Kingdom, European Union, and other IEC-standard regions, the primary side operates at 11kV, while the secondary side provides 230V single phase and 400V three phase supplies to residential, commercial, and industrial users.

Three Phase Transformer

Three phase transformers are widely used in power generation stations to step up voltages for long-distance transmission and to supply three phase power to heavy-duty customers. They serve industries and large commercial facilities that require high power demand, such as factories, data centers, and production plants—just as a multi-lane highway supports far more vehicles than a single-lane road.

Recommended resource : Difference between Circuit Breaker and Isolator / Disconnector

Key Differences Between 1-Φ and 3-Φ Transformers

The following points explain the main differences between single phase (1-Φ) and three phase (3-Φ) transformers in terms of design, connection, voltage levels, and usage.

Single Phase Transformer Three Phase Transformer
Has one set of primary and secondary windings, commonly used in North America. Has three sets of primary and secondary windings, connected in Star (Y) or Delta (Δ) configurations.
Consists of a single unit containing two windings—Primary and Secondary. Acts as a combined bank of three single phase transformers built into one integrated unit.
The primary winding (usually the lower voltage layer) and the secondary winding (higher voltage layer) are wound on the same magnetic core. Both are electrically insulated using materials like transformer oil, which also serves as a cooling medium. The primary and secondary windings can be connected in different ways, including:
Delta–Delta (Δ-Δ)
Delta–Star (Δ-Y)
Star–Star (Y-Y)
Star–Delta (Y-Δ) depending on the system’s requirement.
The primary is connected to 7200V in the US and 11kV in the UK/EU, while the secondary provides 120V & 240V in the US and 230V in the UK/EU. The primary also connects to 7200V (US) and 11kV (UK/EU), but the secondary delivers both single phase and three phase voltages such as 120V & 240V, 208V, 277V, 480V (US) and 230V (1P) or 400V (3P) (UK/EU).
Provides single phase supply through one Line and one Neutral conductor (1L + 1N). Provides three phase supply through three Line conductors and, if required, a Neutral wire (3L + 1N).
Cannot generate a three phase supply from a single phase transformer. Can provide both single phase and three phase outputs from the same transformer.
Converting a three phase supply from a single phase transformer requires extra equipment and is costly and complex. No extra devices are needed to obtain single phase power; it’s an inherent feature of the transformer.
Has lower power transmission capacity since it operates with one phase conductor. Offers higher power transmission capacity due to three conductors carrying power simultaneously.
Cheaper and more economical for light-duty use. More expensive because of its larger size and higher rating.
Compact and lightweight, easy to install. Larger and heavier, suitable for industrial setups.
Designed for small loads and low power ratings. Built for high power ratings and heavy loads.
If a fault occurs, the entire connected system shuts down. If a fault occurs in one line, the other two lines can still operate normally.
Commonly used for power distribution in residential and domestic applications. Mainly used for power transmission in industrial and commercial sectors, as well as power generating stations.

In summary, a single phase transformer is best suited for light electrical loads, such as in homes, while a three phase transformer efficiently handles large-scale power distribution and industrial applications, ensuring stability and reliability in high-demand systems.

Related Posts :

Why are Stones Used in an Electrical Substation

Why are Stones Used in an Electrical Substation?

Why are Stones, Pebbles, Grit, and Gravel Used in a Switchyard? In an electrical substation, you’ll find many types of…

Read More
Difference between Circuit Breaker and Isolator Disconnector

Difference between Circuit Breaker and Isolator / Disconnector

Difference Between Circuit Breaker and Isolator / Disconnector Electrical safety is something everyone understands is important, but many people don’t…

Read More
Why is the Grounding Wire Bare and Not Insulated

Why is the Grounding Wire Bare and Not Insulated?

Why is Mostly Solid Bare Conductor Used for Grounding Instead of Insulated Wire? A ground wire, also called a grounding…

Read More
Why Does the USA Use 120V While Most of the World Uses 230V

Why Does the USA Use 120V While Most of the World Uses 230V?

Why Does the USA Use 120V While Most of the World Uses 230V? In the United States, the standard household…

Read More
Why is an Electric Motor Rated in kW instead of kVA

Why is an Electric Motor Rated in kW instead of kVA?

Why are Electric Motors Rated in kW or Horsepower (hp) and Not in kVA? We know that a transformer is…

Read More
Why Don’t Birds and Squirrels Get Electrocuted on Power Lines?

Why Don’t Birds and Squirrels Get Electrocuted on Power Lines?

Why Don’t Birds Sitting on Power Lines Get Electrocuted? We often say that electricity is both our best friend and…

Read More

Leave the first comment

Follow Us
Engineering Reference
Subscribe to our

Newsletter

We will update you with all the latest books and references.